Sample
Pretreatment and Detection
Related
Articles:
|
41
|

|
Hwisoo
Kim, Bumsoo Kim, Soo Jee Kim, Yejin Choi, Irene Hae-Rim Kim, Jieun Han, Young-Gyun
Park, Yong-Mahn Han, Je-Kyun Park, "Reconfigurable hanging drop microarray
platform for on-demand preparation and analysis of spheroid array," Adv.
Healthcare
Mater., 13
(22), 2400501 (2024).
OPEN
ACCESS
Supporting
Info.: Word
(docx, 11.9 MB), Video
S1 (mp4, 4.2 MB), Video
S2 (mp4, 7.9 MB,
Video
S3 (mp4, 817.7 KB),
Video
S4 (mp4, 1.2 MB), and
Video S5 (mp4, 2.2 MB)
Hot
Topic: Tumors and Cancer
Featured
on the Frontispiece in Advanced Healthcare Materials
|
40
|

|
Jieun
Han, Hye Jin Lim, Juhwan Park, Dong Hyun Han, Dong-Myung Kim, Je-Kyun Park, "On-chip
microfluidic dual detection of amino acid metabolism disorders using cell-free
protein synthesis,"
Biosens.
Bioelectron., 222, 114936 (2023). 
Supporting
Info.: Video
S1 (mp4, 4 MB), Word
(docx, 8 MB)
|
39
|

|
Hyewon
Roh, Hwisoo
Kim, Je-Kyun Park, "Construction of a fibroblast-associated tumor spheroid
model based on a collagen drop array chip," Biosensors,
11 (12), 506 (2021). OPEN
ACCESS
Supporting
Info. (pdf, 729 KB)
|
38
|

|
Ariel
J. Lee, Dongjo Yoon, SeungYoon Han, Herve Hugonnet, WeiSun Park, Je-Kyun Park,
Yoonkey Nam, YongKeun Park, "Label-free monitoring of 3D
cortical neuronal growth in vitro using optical diffraction
tomography," Biomed. Opt. Express, 12 (11), 6928-6939
(2021).
OPEN
ACCESS
|
37
|

|
Hwisoo
Kim, Hyewon
Roh, Haseong Kim, Je-Kyun Park, "Droplet contact-based spheroid transfer technique as
a multi-step assay tool for spheroid arrays," Lab
Chip,
21
(21), 4155-4165 (2021). 
Supporting
Info. (pdf, 547 KB), Movie 1 (mp4, 3064 KB), Movie 2 (mp4, 5376
KB), and Movie 3 (mp4, 540 KB)
|
36
|

|
Advances
in design position push-button mechanisms for future use in biomicrofluidic
applications -- by Adam Liebendorfer, Scilight,
2021, 281108 (2021); https://doi.org/10.1063/10.0005665
|
35
|

|
Juhwan
Park, Je-Kyun Park, "Pushbutton-activated
microfluidic cartridge as a user-friendly sample preparation tool
for diagnostics," Biomicrofluidics, 15
(4), 041302 (2021). 
Invited
Perspective
Featured
Article (July 9, 2021)
Highlighted
in AIP Scilight (Advances in design position push-button
mechanisms for future use in biomicrofluidic applications --- by
Adam Liebendorfer)
|
34
|

|
Juhwan
Park, Kyoung G. Lee, Dong Hyun Han, Ji-Soo Lee, Seok Jae Lee, Je-Kyun Park,
"Pushbutton-activated microfluidic dropenser for droplet digital PCR,"
Biosens.
Bioelectron., 181, 113159 (2021). 
Supporting
Info.: Video
S1 (mp4, 654 KB), Word
(docx, 2MB)
|
33
|

|
Yoo
Min Park, Juhwan Park, Sun Young Lim, Yeji Kwon, Nam Ho Bae, Je-Kyun Park, Seok Jae Lee,
"Integrated pumpless microfluidic chip for the detection of foodborne pathogens
by polymerase chain reaction and electrochemical analysis," Sens. Actuators B Chem., 329,
129130 (2021).
The first two authors
contributed equally to this work.
|
32
|

|
Juhwan Park, Hwisoo
Kim, Je-Kyun Park, "Microfluidic channel-integrated hanging drop array
chip operated by pushbuttons for spheroid culture and analysis," Analyst, 145
(21), 6974-6980 (2020). 
Supporting
Info. (pdf, 349 KB), Movie
1 (mp4, 273 KB)
|
31
|

|
Juhwan Park, Dong
Hyun Han, Sang-Hyun Hwang, Je-Kyun Park, "Reciprocating flow-assisted
nucleic acid purification using a finger-actuated microfluidic device," Lab
Chip, 20
(18),
3346-3353 (2020). 
The first two authors
contributed equally to this work.
Supporting
Info. Movie
1 (mp4, 2535 KB), Movie
2 (mp4, 2829 KB)
|
30
|

|
Chi Hyun Kim, Juhwan
Park, Soo Jee Kim, Dae-Hyun Ko, Song Ha Lee, Seok Jae Lee, Je-Kyun Park, Moon-Keun Lee, "On-site extraction
and purification of bacterial nucleic acids from blood samples using an unpowered
microfluidic device," Sens. Actuators B Chem., 320,
128346 (2020).
The first two authors
contributed equally to this work.
Supporting
Info. (docx, 44 KB)
|
29
|

|
Younggeun
Jo, Juhwan Park, Je-Kyun Park,
"Colorimetric
detection of Escherichia coli O157:H7 with signal enhancement
using size-based filtration on a finger-powered microfluidic device," Sensors,
20 (8) 2267 (2020).
OPEN
ACCESS
The first two authors
contributed equally to this work.
|
28
|

|
Inside
Back Cover of Lab on a Chip (Issue 7, 2020):
Critical
review of user-friendly microfluidic devices towards practical sample
preparation in point-of-care-testing, which can facilitate mixing
of multiple reagents, effective reaction between biomolecules, separation
of target particles, and compartmentalization for high-throughput
or digital analysis.
|
27
|

|
Juhwan Park, Dong
Hyun Han, Je-Kyun
Park, "Towards practical sample preparation in point-of-care testing: user-friendly
microfluidic devices,"
Lab
Chip, 20 (7), 1191-1203 (2020). 
Critical
Review
Featured on the Inside
Back Cover
Article
|
26
|

|
Juhwan Park, Je-Kyun
Park, "Finger-actuated microfluidic display for smart blood typing,"
Anal. Chem., 91
(18), 11636-11642 (2019). 
Supporting
Info. (pdf, 1.32 MB), Movie
(mp4, 429 KB)
|
25
|

|
Juhwan Park,
Hyewon
Roh, Je-Kyun Park, "Finger-actuated microfluidic concentration
gradient generator compatible with a microplate," Micromachines,
10
(3), 174 (2019).
OPEN
ACCESS
The first two authors
contributed equally to this work.
|
24
|

|
Seonhee Lee, Juhwan Park, Je-Kyun Park, "Foldable
paper-based analytical device for the detection of an acetylcholinesterase
inhibitor using an angle-based readout," Sens. Actuators B Chem.,
273, 322-327 (2018).
|
23
|

|
Juhwan
Park, Je-Kyun Park,
"Finger-actuated microfluidic
device for the blood-cross matching test,"
Lab Chip,
18 (8), 1215-1222 (2018). 
Supporting
Info. (pdf, 526 KB)
|
22
|

|
Joong
Ho Shin, Jisoo Hong, Hyeyun Go, Juhwan Park, Minsuk Kong, Sangryeol
Ryu, Kwang-Pyo Kim, Eunjung Roh, Je-Kyun Park, "Multiplexed
detection of foodborne pathogens from contaminated lettuces using
a handheld multistep lateral flow assay device," J. Agric.
Food Chem., 66 (1), 290-297 (2018).
The first two authors
contributed equally to this work.
Supporting
Info. (pdf, 194.55 KB)
|
21
|

|
GwangSik Park, Dongsik Han, GwangSu Kim, Seungwoo Shin,
Kyoohyun Kim, Je-Kyun Park, YongKeun Park,
"Visualization and label-free quantification of microfluidic
mixing using quantitative phase imaging," Appl.
Optics, 56 (22), 6341-6347 (2017).
The first
three authors contributed equally to this work.
|
20
|

|
Jae Hoon Oh, Moon
Kyoo Park, Seong Wook Kim, Je-Kyun Park, "A
fully automated analyzer for multiple detection of allergen-specific immunoglobulin
E," Anal.
Methods, 7
(20), 8889-8895 (2015).
|
19
|

|
Do-Hyun Lee, Miran Jang, Je-Kyun Park, "Rapid one-step purification of
single-cells encapsulated in alginate microcapsules from oil to aqueous phase
using a hydrophobic filter paper: Implications for single-cell experiments," Biotechnol.
J., 9 (10), 1233-1240 (2014).

Supporting
Info. (pdf, 361 KB)
|
18
|

|
Jung
Kim, Seyong Kwon, Je-Kyun Park, Inkyu Park, "Quantum dot-based immunoassay
enhanced by high-density vertical ZnO nanowire array," Biosens. Bioelectron., 55,
209-215 (2014).
The first two authors contributed equally to this
work
Supporting
Info. (docx, 3,133 KB)
|
17
|

|
Dae-Sik
Lee, Byoung Gu Jeon, Chunhwa Ihm, Je-Kyun Park, Mun Yeon Jung, "A simple
and smart telemedicine device for developing regions: a pocket-sized colorimetric
reader," Lab Chip, 11 (1), 120-126 (2011).
Supporting
Info. (pdf, 331 KB) and Movie
(mp4, 8.63 MB)
Lab
on a Chip Blog: Medicine gets smart (2010. 11. 26)
Selected
for Vir. J. Bio. Phys. Res. (2010)/ Volume 20 / Issue 12 / INSTRUMENTATION
DEVELOPMENT (2010. 12. 15)
|
16
|

|
Sungyoung
Choi, Myung Gwon Lee, Je-Kyun Park,
"Microfluidic parallel circuit for measurement of
hydraulic resistance,"
Biomicrofluidics, 4 (3),
034110
(2010).

|
15
|

|
Sungyoung
Choi, Je-Kyun Park, "Microfluidic
rheometer for characterization of protein unfolding and aggregation in microflows," Small,
6 (12), 1306-1310 (2010). 
|
14
|

|
Jaeduck Jang, Chae
Yun Bae, Je-Kyun Park, Jong
Chul Ye, "Self-reference quantitative phase microscopy for
microfluidic devices,"
Opt. Lett.,
35 (4), 514-516 (2010).
Selected
for Vir. J. Biomed. Opt. (2010)/ Volume 5 / Issue 5 / Microfluidics
and Nanofluidics
Selected
for Vir. J. Bio. Phys. Res. (2010)/ Volume 19 / Issue 6 / INSTRUMENTATION DEVELOPMENT
(2010. 3. 15)
|
13
|

|
Sungyoung
Choi, Seung-Hoon Kim, Je-Kyun Park, "Optical path-length modulation for
three-dimensional particle measurement in mirror-embedded microchannels,"
Lab Chip, 10 (3), 335-340 (2010). 
|
12
|

|
Joo H.
Kang,
Bumjun
Kim,
Je-Kyun
Park,
"Microfluidic
pycnometer for in situ analysis of fluids in
microchannels,"
Anal.
Chem., 81 (7),
2569-2574 (2009).
Supporting Info. (pdf, 232 KB)
Supporting Info.: Video clip
(mp4, 286 KB)
|
11
|

|
Sungyoung Choi, Je-Kyun Park, "Mirror-embedded microchannel for three-dimensional
measurement of particle position," Appl.
Phys. Lett., 93 (19),
191909
(2008).
Supporting
Info. (pdf, 197.9 KB)
|
10
|

|
Sungho
Ko, Bumjun Kim, Seong-Sik Jo, Se Young Oh, Je-Kyun Park, "Electrochemical detection of cardiac troponin I using a
microfluidic chip with the surface-functionalized
poly(dimethylsiloxane) channel," Biosens.
Bioelectron.,
23 (1), 51-59
(2007).

|
9
|

|
Jeong-Gun Lee, Kyusik Yun, Guei-Sam Lim, Sang Eun Lee, Suhyeon
Kim, Je-Kyun Park, "DNA biosensor based on the electrochemiluminescence of
Ru(bpy)32+ with DNA-binding
intercalators," Bioelectrochemistry, 70 (2),
228-234 (2007).

|
8
|

|
Yoonhee
Jang, Se Young Oh, Je-Kyun Park, "In situ electrochemical enzyme immunoassay on a microchip with
surface-functionalized poly(dimethylsiloxane) channel,"
Enzyme Microb. Technol., 39 (5),
1122-1127 (2006).
|
7
|

|
Suhyeon
Kim, Guei-Sam Lim, Sang Eun Lee, Jeong-Gun Lee, Kyusik Yun,
Je-Kyun Park, "DNA chip replication for a personalized DNA chip,"
Biomol. Eng., 23 (2-3), 129-134
(2006).

|
6
|

|
Wonjae
Choi, Je-Kyun Park, "A bio-fluidic device for adaptive sample pretreatment and its
application to measurement of Escherichia coli
concentration," Biotechnol. Bioprocess Eng.,
11 (1), 54-60 (2006).
|
5
|

|
Sungyoung Choi, Je-Kyun Park,
"Microfluidic
system for dielectrophoretic separation based on a trapezoidal
electrode array," Lab Chip, 5 (10),
1161-1167 (2005).
Spporting
Info.: Video
0 (Fig.3a),
Video 1
(Fig.
5a),
Video
2 (Fig.
5b),
Video
3 (Fig. 5c)
|
4
|
|
Joo H.
Kang, Je-Kyun Park, "Development of a microplate reader compatible microfluidic
device for enzyme assay," Sens. Actuators B
Chem., 107 (2), 980-985 (2005).
|
3
|

|
Ju Hun
Yeon, Je-Kyun Park, "Cytotoxicity test based on electrochemical impedance
measurement of HepG2 cultured in microfabricated cell
chip," Anal. Biochem., 341 (2),
308-315 (2005).
Selected in National Cancer Institute (NCI)
Nanotech News (May 23,
2005)
|
2
|

|
Yuheon
Yi, Je-Kyun Park, "Fabrication of electrochemical sensor with tunable electrode
distance," J. Semiconductor Technol. Sci., 5 (1), 30-37 (2005).
|
1
|

|
Suhyeon Kim, Je-Kyun Park, "Development of a test strip reader for a lateral flow membrane-based immunochromatographic assay," Biotechnol. Bioprocess Eng., 9 (2), 127-131 (2004). |